Unipos FD8030 Optical Smoke Detector
Conventional Optical-Smoke DetectorWith mounting baseTwo LED indicatorsSupply voltage 10-30V DCCurrent consumption in Alarm condition: 8mA/10V DC, 25mA/30V DCCurrent consumption in Standby mode - 120µAOutput in Alarm condition for LED indicatorOperation temperature range -10°C iki +55°CDegree of Protection IP43Complies with EN54-7
€13.58
NewOut-of-Stock
Signaline HD+ controller for programmable heat-sensitive cable
Out-of-Stock
Type: Controller for programmable heat-sensitive cable Model: Signaline HD+ Controller Certifications: EN54-22:2015+A1:2020 (Class A1I, A2I, BI), UL521 Operating temperature: -20°C to +50°C Operating voltage: 20Vdc - 30Vdc (VdS EN54), 23Vdc - 30Vdc (UL) Current consumption (without LCD backlight): 31mA @ 20Vdc to 20mA @ 30Vdc Current consumption (without LCD and alarm): 61mA @ 20Vdc to 39mA @ 30Vdc Current consumption (with LCD and alarm): 85mA @ 20Vdc to 59mA @ 30Vdc Alarm output: Alarm & Pre-alarm FORM C, 2A @ 30Vdc (resistive, 60W), 0.25A @ 250Vac (62.5VA) Fault output: Normally closed opto-isolated phototransistor (Max V: 35Vdc, Max I: 80mA, Max P: 150mW) Modbus output: 2-wire RS-485 Modbus RTU or ASCII IP and impact rating: IP65 (IK08) Weight: 860 g
NewOut-of-Stock
Signaline HD+ EOL controller for programmable heat-sensitive cable
Out-of-Stock
Type: End-of-line controller Model: Signaline HD+ End of Line Application: For programmable heat-sensitive cable Alarm class: EN54-22:2015+A1:2020 (Class A1I, A2I, BI), UL521 Operating temperature: -40°C to +125°C Mounting: External fixing bracket (included) Enclosure material: Aluminium IP and impact rating: IP65 Weight: 115 g
NewOut-of-Stock
Combined smoke + heat conventional detector UNIPOS FD8060
Out-of-Stock
Conventional line monitoring module – Designed to connect conventional fire alarm line (with up to 32 fire detectors) as a part of the addressable fire alarm system IFS7000. The built-in short circuit isolators are available. FD7201S is power supplied via the power loop and up to 125 modules can be connected in each of the signal loops. It satisfies the requirements of the European Standard EN54-17 & EN54-18.
Out-of-Stock
UNIPOS FD7201S Conventional line monitoring module
Out-of-Stock
Conventional line monitoring module – Designed to connect conventional fire alarm line (with up to 32 fire detectors) as a part of the addressable fire alarm system IFS7000. The built-in short circuit isolators are available. FD7201S is power supplied via the power loop and up to 125 modules can be connected in each of the signal loops. It satisfies the requirements of the European Standard EN54-17 & EN54-18.
Signaline FT-185-R
Signaline Fixed Temperature Heat Sensing Cable (Signaline FT) detects a build up of heat anywhere along its length. When any point along the length of the cable reaches a predetermined temperature an alarm is initiated
€11.83
Out-of-Stock
UNIPOS FD7120 heat detector base
Out-of-Stock
The fire detector provides reliable early warning of a Fire condition upon reaching a rate of rise of the temperature or fixed temperature threshold in the protected premises. The temperature class (A1R, A2R or BR) is in compliance with the European Standard EN54-5 and is programmable by Fire Control Panel IFS7002. The fire detector is suitable for premises with normal ambient temperature, without possible sudden changes.
Out-of-Stock
UNIPOS FD7150 Manual Call Point
Out-of-Stock
It is designated to release a signal for a Fire condition to the Fire Control Panel IFS7002 upon manual activation by breaking the glass on the place, signed with arrows. The light indication for activating the manual call point is provided by a red LED. There is possibility for testing by a special key.It satisfies the requirements if the European Standard EN54-11 for a type A manual call point and EN54-17.
SIGNALINE cable FT-78-EN
Fixed alarm temperature of 78°CNo false alarmsUp to 1.000m per zoneEN54-28:2016 approved
€5.72
SIGNALINE cable FT-88-EN
Fixed alarm temperature of 88°CNo false alarmsUp to 1.000m per zoneEN54-28:2016 approved
€5.72
Out-of-Stock
Signaline FT-68
Out-of-Stock
Signaline Fixed Temperature Heat Sensing Cable (Signaline FT) detects a build up of heat anywhere along its length. When any point along the length of the cable reaches a predetermined temperature an alarm is initiated
Signaline FT-88
Signaline Fixed Temperature Heat Sensing Cable (Signaline FT) detects a build up of heat anywhere along its length. When any point along the length of the cable reaches a predetermined temperature an alarm is initiated
€5.31
Out-of-Stock
Signaline FT-68R
Out-of-Stock
Signaline Fixed Temperature Heat Sensing Cable (Signaline FT) detects a build up of heat anywhere along its length. When any point along the length of the cable reaches a predetermined temperature an alarm is initiated.
Signaline FT-105R (nylon)
Signaline Fixed Temperature Heat Sensing Cable (Signaline FT) detects a build up of heat anywhere along its length. When any point along the length of the cable reaches a predetermined temperature an alarm is initiated
€6.44
Signaline FT-105
Signaline Fixed Temperature Heat Sensing Cable (Signaline FT) detects a build up of heat anywhere along its length. When any point along the length of the cable reaches a predetermined temperature an alarm is initiated
€5.31
Signaline HD-R
Durable stainless steel protective braidUnaffected by steam, dust, humidity and smokeAutomatically resets when cool
€9.41
Out-of-Stock
UNIPOS FD7204 Sounder (indoor)
Out-of-Stock
Addressable sounder beacon device – base with built-in short-circuit isolator and accumulator battery, is used for sound and flash indication on registered events by the Interactive fire alarm panel IFS7002. The FD7204 is used for indoor applications.