XP95 Sounder Beacon Base with Isolator
Turime sandėlyje
The Sounder Visual Indicator Base is a loop-powered sounder and visual indicator combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas.Two volume ranges 55-75dB(A) and 75-91dB(A)Visual indicator flash rate of once per secondSynchronisation of 'alert' and 'evacuate' tonesSynchronisation of visual indicator flashIndividual and group addressingUnique acoustic and visual indicator self-testBuilt-in Isolator
XP95 Universal address card
Out-of-Stock. Ask the seller
Universal address cards, known as XPERT cards are supplied as standard. The XPERT card holds the device address data and is installed in the mounting base. As the address data is stored in the mounting base, this means that the address remains the same, even if the device is replaced for maintenance.
UNIPOS FD7120 heat detector base
Out-of-Stock. Ask the seller
The fire detector provides reliable early warning of a Fire condition upon reaching a rate of rise of the temperature or fixed temperature threshold in the protected premises. The temperature class (A1R, A2R or BR) is in compliance with the European Standard EN54-5 and is programmable by Fire Control Panel IFS7002. The fire detector is suitable for premises with normal ambient temperature, without possible sudden changes.
XP95 Isolating Base
Turime sandėlyje
Up to 20 detectors or their equivalent load, may be installed between isolating basesHigh brightness LEDDetects wiring short-circuitsMinimises disruption from short circuits
UNIPOS FD7150 Manual Call Point
Out-of-Stock. Ask the seller
It is designated to release a signal for a Fire condition to the Fire Control Panel IFS7002 upon manual activation by breaking the glass on the place, signed with arrows. The light indication for activating the manual call point is provided by a red LED. There is possibility for testing by a special key.It satisfies the requirements if the European Standard EN54-11 for a type A manual call point and EN54-17.
XP95 Heat Detector
Turime sandėlyje
The XP95 heat detector is distinguishable from the smoke detectors by its low airflow resistance case which allows good contact between the sensing thermistor and the surrounding air. The device monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The voltage signal is processed and transmitted to the control equipment in exactly the same way as in the case of the ionisation smoke detector. A heat detector for use in ambient safe temperatures of up to 50°C and which reaches the alarm level at 90°C is also available.
XP95 Intelligent Manual Call Point (discovery)
Turime sandėlyje
Easy access, front reset mechanismE-Z fit connector system for installationEN 54-11 & EN 54-17 Certified (Red version only)170° viewable LEDContinuity link for cable insulation testingSuitable for semi flush or surface mounting