XP95 Intelligent Manual Call Point (discovery)
Turime sandėlyje
Easy access, front reset mechanismE-Z fit connector system for installationEN 54-11 & EN 54-17 Certified (Red version only)170° viewable LEDContinuity link for cable insulation testingSuitable for semi flush or surface mounting
UNIPOS FD7201S Conventional line monitoring module
Out-of-Stock. Ask the seller
Conventional line monitoring module – Designed to connect conventional fire alarm line (with up to 32 fire detectors) as a part of the addressable fire alarm system IFS7000. The built-in short circuit isolators are available. FD7201S is power supplied via the power loop and up to 125 modules can be connected in each of the signal loops. It satisfies the requirements of the European Standard EN54-17 & EN54-18.
UNIPOS FD7204 Sounder (indoor)
Out-of-Stock. Ask the seller
Addressable sounder beacon device – base with built-in short-circuit isolator and accumulator battery, is used for sound and flash indication on registered events by the Interactive fire alarm panel IFS7002. The FD7204 is used for indoor applications.
XP95 Intelligent Open-Area Sounder (waterproof)
Turime sandėlyje
The Intelligent Open-Area Sounder has been designed for use in open areas and can be connected to any Discovery or XP95 system.Self-test fault monitoringChoice of tones on standard device: Apollo, Slow Whoop and DINTwo volume settings 92dB(A) and 100dB(A)Synchronisation of tonesIndividual and group addressingBuilt in isolatorRed or white optionsLoop-poweredIP65 rated
Apollo XP95 Mini Switch Monitor - 55000-760APO
Out-of-Stock. Ask the seller
The Mini Switch Monitor is an interface within an entirely new housing. Designed in response to customer feedback, the smaller Mini Switch Monitor can be fitted onto a 35mm DIN-Rail with a twist-click motion or mounted in an enclosure such as a manual call pointIt is designed to monitor the state of one or more single pole, volt free contacts connected to a single pair of cables and to report the status to Apollo compatible control equipment
Input/output module 2/2, APOLLO XP95, SA4700-10...
Turime sandėlyje
Improved design for ease of wiring meaning faster installation Contains controllable isolatorAddress range 1 - 254Nine pre-configured modes, including compatibility mode from XP95/Discovery to CoreProtocol systemsFailsafe mode (meets BS 7273-4 requirements)Configurable input stylesEarth fault monitoring
Xp95 Input/Output Unit
Out-of-Stock. Ask the seller
The Input/Output Unit provides a voltage-free, double pole changeover (DPCO) relay output, a single monitored switch input and an unmonitored, non-polarised opto-coupled input.
Loop-Powered Visual Indicator for XP95
Turime sandėlyje
The Loop-Powered Visual Indicator is a local-area visual indicator designed for indoor use. The Visual Indicator has been developed as a supplement to sounders for use in situations where there is a risk that sounders will not be heard.High intensity LEDsMore reliable than xenon visual indicatorsAutomatic LED checkLockableWide angle of visibilityEnables DDA complianceSynchronised flashCan be used with Discovery or XP95
XP95 Zone Monitor
Turime sandėlyje
The Zone Monitor powers and controls the operation of a zone of up to 20 Apollo Series 65 or Orbis fire detectors from a Discovery or XP95 loop
XP95 Addressable Output Unit with Isolator
Out-of-Stock. Ask the seller
The Output Unit provides a voltage free single pole, changeover relay output. It is a simplified version of the Input/Output Unit without circuitry for monitoring inputs.Capable of switching up to 30V at 1AVoltage free, change-over relay outputShort-circuit isolatorCapable of switching up to 30V at 1AWall mounted (surface)Dimensions: 150x90x48mm
Intelligent Open-Area Sounder Visual Indicator ...
Out-of-Stock. Ask the seller
The Intelligent Open-Area Sounder Visual Indicator is designed for use in open areas and can be connected to an Apollo Discovery or XP95 system.Self-test monitoringChoice of tones on standard device: Apollo, Slow Whoop and DINTwo volume settings 92dB(A) and 100dB(A)Individual and group addressingSycronisation of tones and flashesBuilt in isolatorLoop-poweredIP65 ratedRed and clear lens options
PREVIDIA LCD repeater
Out-of-Stock. Ask the seller
For address control panelPrevidia MAX and Previdia Compact panel repeater;4.3" touchscreen display;TCP/IP conection for networking;HORNET+ interface;
MEDC BG2 Manual Alarm Call Point (flammable atm...
Turime sandėlyje
This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is requiredZone 0, Zone 1 and Zone 2 useExed, Exia or weatherproofATEX approvedBASEEFA certifiedIP66 and IP67Certified temperature: –40°C to +50°C (Model dependent)Corrosion resistant red painted GRPRetained stainless steel cover screwsOptional lift flapKey operated test facilityLightweight and robustBreakglass hammer available (Contact sales office for details)