Salicru UPS SLC-1000-TWIN RT3 (1000VA/1000W, Rack/Tower, LCD, Online, 8 C13, SNMP)
- Type: UPS
- Model: SLC-1000-TWIN RT3
- Manufacturer code: 6B4AA000001
- Power: 1000VA / 1000W
- Design: Rack/Tower
- Display: LCD
- Ports: 8×C13, RS232, USB B, 2xRJ45
- LAN card compatibility: Yes
- UPS type: Online
- Pure sine wave
- EPO: Emergency power off
- Dimensions: 445×438×86 mm (D×W×H)
- Batteries: 3×12V/7Ah
- Case: Metal
- External battery pack support
|
DPD Pick up terminal. Delivery within 1-8 days. ( from 3,00 €) |
|
Delivery via DPD courier service. Delivery within 1-8 days. ( from 4,00 €) |
- General
- Model Code6B4AA000001
- Power (VA/W)1000/1000
- Output Sockets8 × IEC C13
- Dimensions (D × W × H mm)445 × 438 × 86
- Weight (Kg)14.0
- TechnologyOn-line double-conversion
- FormatConvertible tower/rack with rotating display
- Input Voltage200/208/220/230/240 V
- Voltage Range110 ÷ 300 V
- Rated Frequency50 / 60 Hz (auto-detection)
- Total Harmonic Distortion (THDi)<5 %
- Power Factor≥0.99
- Output Voltage200/208/220/230/240 V
- Voltage Accuracy±1%
- Total Harmonic Distortion (THDv)<1 % linear load / <5 % non-linear load
- Synchronised Frequency50 ±5 Hz/60 ±6 Hz
- On-line Performance≥89 ÷ 93 %
- Eco-mode Performance≥96 ÷ 97 %
- Admissible Overloads (Battery Mode)105 ÷ 125 % for 2 min / 125 ÷150 % for 10 s / >150 % for 500 ms
- Admissible Overloads (Bypass Mode)105 ÷ 125 % for 10 min / 125 ÷150 % for 5 min / >150 % for 500 ms
- Admissible Overloads (In-line Mode)105 ÷ 125 % for 5 min / 125 ÷150 % for 30 s / >150 % for 500 ms
- Programmable SocketsYes, for critical/non-critical loads (4/4)
- Battery TypePb-Ca sealed, AGM, maintenance-free
- Charge TypeSmart charge with 3 modes
- Recharge Time3 hours to 90%
- Maximum No. of EBMs4
- Charging Current1.5 A (8 A for B1 devices)
- Communication PortsUSB-HID/RS-232/RJ-45/HDMI for Wi-Fi dongle
- Intelligent SlotFor SNMP/AS400/MODBUS
- Monitoring SoftwareSoftware for Windows, Linux, Mac / App for iOS & Android / Web portal
- Cold StartYes (Start-up from batteries)
- Emergency Stop (EPO)Yes
- Operating ModesEco-mode, Frequency converter (CVCF)
- Operating Temperature0º C ÷ +50º C
- Relative HumidityUp to 95%, non-condensing
- Maximum Operating Altitude3000 MASL
- Acoustic Noise at 1m<45 dB ÷ <50 dB at full load / <36 dB ÷ <46 dB at 70% load
- StandardsSafety: EN IEC 62040-1, EMC: EN IEC 62040-2(C2), Operation: VFI-SS-31 (EN 62040-3)
- CertificationsISO 9001, ISO 14001, ISO 45001