Control panel S16 cmR+Voucher SECOLINK (5/10 zones, max 16 zones 3PGM, 4 areas)
zoom_out_map
chevron_left chevron_right

Control panel S16 cmR+Voucher SECOLINK (5/10 zones, max 16 zones 3PGM, 4 areas)

  • 5/10 zones
  • Maximum 16 zones
  • 3PGM
  • 4 areas
  • 16 timers
  • Integrated GSM modem with eSIM card and 2-year plan
€131.27 (tax incl.) €131.27 (tax excl.)
Tax included
check Turime sandėlyje

archive

DPD Pick up terminal. Delivery within 1-8 days.  ( from 3,00 €)

local_shipping

Delivery via DPD courier service. Delivery within 1-8 days.  ( from 4,00 €)

  • General
  • Maximum number of zones in the system16
  • Number of PGM outputs on the board3
  • Maximum number of PGM outputs in the system16
  • Number of users + installer codes31+1
  • Attack codeYra
  • Recovery of user and installer codesYra
  • Key-switch area (key-switch)Yra
  • Areas4
  • Common corridor areaYra
  • Number of timers in the system16
  • Maximum number of control panels/modules in the system3
  • Compatibility with control panelsVisi SECOLINK valdymo pultai
  • Event log volumeCentralėje - 256, komplekte su vald. pultu - 512
  • Interface with transmitters and communicators of other manufacturersNėra
  • Data bus protocolKRBUS
  • The area of the sensor (roller) that detects the lifting of blindsYra
  • Vibration detection sensor areaYra
  • Sensitivity (speed) of the vibration detection zone0,01 - 0,25 sek.
  • Sensor area sensitivity (speed)0,1 - 2,5 sekundės
  • Nominal power supply voltage (AC) of the control unit~18 - 20 V
  • Minimum power supply voltage (AC) of the control unit~16 V
  • Maximum power supply voltage (AC) of the control unit~22
  • Maximum long-term control unit output current (I+AUX + I+BELL + IBATTERY CHARGE)≤0,7 A
  • Maximum AC primary slow-blow fuse current250 mA
  • Maximum current consumed from the AC mains150 mA
  • Minimum voltage of +AUX, +BELL outputs12 V
  • Maximum voltage of +AUX, +BELL outputs13,9 V
  • Maximum outgoing +AUX current+0,5 A
  • Maximum short-term output +BELL current (with battery)+2 A
  • Maximum inrush current of -PGM1-0,15 A
  • Maximum inrush current of -PGM2-0,15 A
  • +BELL, +AUX short circuit, overload protectionElektroninė
  • Battery charging, +BELL, +AUX current measurementYra
  • Disconnecting a faulty batteryYra
  • Maximum battery charging current+0,2 A
  • Maximum current of the battery circuit fast-blow fuse3,15 A
  • The control unit disconnects the battery when the battery voltage is below9,5 V
  • Product compliance with standardsEN50131, Grade2
  • A backup power supply is recommended12 V, 2,2 - 7Ah
  • Overall dimensions W x H mm145 x 77
  • Compliance of the product with environmental protection standardsROHS
  • Operating temperatureNuo -10oC iki +50oC
  • Remote programming of control panel settingsYra
CASS16CMRVOUCHER