GSM control panel SECOLINK GSV4
zoom_out_map
chevron_left chevron_right

GSM control panel SECOLINK GSV4

  • 6 zone control panel
  • 3 PGM
  • 5 users
  • Area 1
  • 512 event memory
  • Alarm notification by GSM call, SMS
  • Voice guide
  • Grade2
€113.44 (tax incl.) €113.44 (tax excl.)
Tax included
block Out-of-Stock. Ask the seller

archive

DPD Pick up terminal. Delivery within 1-8 days.  ( from 3,00 €)

local_shipping

Delivery via DPD courier service. Delivery within 1-8 days.  ( from 4,00 €)

In-built wired zones on board6
RF Jamming detectionYes
PGM on board3
User codes5
Defaulting user codeYes
Key switch zoneYes
Partitions1
System timers16
Event log size512
Reporting to CMS formatCID via GPRS
Total number of protocols, used for CMS reportingE2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA
Compatible with SG-SYSTEM II, III IP cardYes
Alarm message for end userGSM calls, SMS
Alarm message for end user by voice clipYes
Voice guide for end userYes
Recordable audio alarm messagesYes
Available language for SMSEnglish, National
System remote control by GSM callArm / disarm / clear alarm / PGM control / zone bypass
emote system control by Android smart phone applicationYes
Remote system control by iPhone smart phone applicationYes
Zone speed (sensitivity)0.1 - 2.5 sec.
Zone loop (detector) typeNC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL
Arming modeAway, Max Away, Night, Stay.
Zone definitionEntry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature.
Zone attributesEnable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night.
PGM definitionFire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, wxit arm status, full arm status, arm/disarm acknowledge, power supply, resettable power supply, fire power supply, timer, mono/bi switch.
PGM attributesInversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, arm notification, disarm notification, clear alarm notification.
Rated voltage of power supply (AC)~20 V
Minimum AC voltage~16 V
Maximum AC voltage
(Note: higher than ~22 V voltage can damage GSV4)
~22 V
Maximum long term output current of GSV4
(I+AUX + I+BELL + battery charge)
0.7 A
Maximum current of slow blowing fuse used in primary AC250 mA
Maximum AC power consumption<30 mA
Minimum voltage on +AUX, +BELL, outputs12 V
Maximum voltage on +AUX, +BELL, outputs13.9 V
Maximum current out of +AUX0.25 A
Maximum current out of +BELL (without battery)0.2 A
Maximum current out of +BELL (with battery)2:00 AM
Maximum current into -PGM1-0.05 A
Maximum current into -PGM2-0.05 A
Short circuit, overload protection of +BELL, +AUXelectronic
Battery charge +BELL, +AUX current measurementYes
Failed (waste) backup battery disconnectionYes
Maximum battery charging current0.25 A
Maximum current of fast blowing fuse used in battery3.15 A
GSV4 disconnects battery when it’s voltage less than9.5 V
Recommended backup power supply12 V, 7 Ah / 20 Hr
Operational complianceEN50131, Grade2
Overall dimensions W x H in mm120 x 64
Environmental complianceROHS
Operating temperatureFrom -10oC to +50oC
Interface for control panel settings programmingUSB
Interface for control panel firmware updateUSB
Remote control panel settings programmingYes, via www.alarmserver.net
CASGSV4
1 kg