GSM control panel SECOLINK GSV4
- 6 zone control panel
- 3 PGM
- 5 users
- Area 1
- 512 event memory
- Alarm notification by GSM call, SMS
- Voice guide
- Grade2
|
DPD Pick up terminal. Delivery within 1-8 days. ( from 3,00 €) |
|
Delivery via DPD courier service. Delivery within 1-8 days. ( from 4,00 €) |
In-built wired zones on board | 6 |
RF Jamming detection | Yes |
PGM on board | 3 |
User codes | 5 |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 1 |
System timers | 16 |
Event log size | 512 |
Reporting to CMS format | CID via GPRS |
Total number of protocols, used for CMS reporting | E2 (Enigma), FIBRO (Sur-gard), CSV (Patriot), SIA |
Compatible with SG-SYSTEM II, III IP card | Yes |
Alarm message for end user | GSM calls, SMS |
Alarm message for end user by voice clip | Yes |
Voice guide for end user | Yes |
Recordable audio alarm messages | Yes |
Available language for SMS | English, National |
System remote control by GSM call | Arm / disarm / clear alarm / PGM control / zone bypass |
emote system control by Android smart phone application | Yes |
Remote system control by iPhone smart phone application | Yes |
Zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
Arming mode | Away, Max Away, Night, Stay. |
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control; 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature. |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night. |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, wxit arm status, full arm status, arm/disarm acknowledge, power supply, resettable power supply, fire power supply, timer, mono/bi switch. |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, arm notification, disarm notification, clear alarm notification. |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage | ~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage GSV4) | ~22 V |
Maximum long term output current of GSV4 (I+AUX + I+BELL + battery charge) | 0.7 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | <30 mA |
Minimum voltage on +AUX, +BELL, outputs | 12 V |
Maximum voltage on +AUX, +BELL, outputs | 13.9 V |
Maximum current out of +AUX | 0.25 A |
Maximum current out of +BELL (without battery) | 0.2 A |
Maximum current out of +BELL (with battery) | 2:00 AM |
Maximum current into -PGM1 | -0.05 A |
Maximum current into -PGM2 | -0.05 A |
Short circuit, overload protection of +BELL, +AUX | electronic |
Battery charge +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | 0.25 A |
Maximum current of fast blowing fuse used in battery | 3.15 A |
GSV4 disconnects battery when it’s voltage less than | 9.5 V |
Recommended backup power supply | 12 V, 7 Ah / 20 Hr |
Operational compliance | EN50131, Grade2 |
Overall dimensions W x H in mm | 120 x 64 |
Environmental compliance | ROHS |
Operating temperature | From -10oC to +50oC |
Interface for control panel settings programming | USB |
Interface for control panel firmware update | USB |
Remote control panel settings programming | Yes, via www.alarmserver.net |