  • Komutatorius 26 prievadų
  • 24 PoE 1 Gb
  • 2-XSFP Gb
  • Combo
  • 17-22 ports >250m/10Mbps (CCTV)
  • Cap 156Mbps
280,04 € (su PVM) 280,04 € (be mok.)
block Neturime sandėlyje. Teirautis

store

Nemokamas prekių atsiėmimas Vilniuje.  (0,00 €) 

archive

Atsiėmimas LP Express paštomate. 1–4 d. d.  (3,00 €) 

archive

Atsiėmimas DPD Pick up paštomate. 1-4 d. d.  (3,00 €)

archive

Atsiėmimas Omniva paštomate. 1 –4 d. d.  (3,00 €) 

local_shipping

Pristatymas per DPD kurjerių tarnybą. 1-4 d. d.  (4,50 €)

  • Pagrindinis
  • Downlink prievadai24*10/100/1000Base-T PoE+ RJ-45(Auto-MDI/MDI-X)
  • Uplink prievadai2*GE Combo Ports(SFP Port is prior to RJ-45 Port)
  • Led indikatoriai1*Power, power supply indicator, 1*PoE-Max, PoE power indicator, 24*Link/Act, port state indicators, 2*SFP port state indicators
  • Dydis440mm*284mm*44mm
  • Įeinanti įtampa100~240V AC, 50~60Hz
  • Energijos sunaudojimas≤410W (Full load including PoE)
  • MedžiagaMetal shell
  • MontavimasRack/Desktop/Wall mounted
  • StandartaiIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x, IEEE 802.3z, IEEE 802.3af, IEEE 802.3at
  • Persiuntimo režimaiStore and Forward
  • MAC adresų lentelė8k, support auto learning
  • Perjungimo talpa156Gbps / non-blocking
  • PoE standartasIEEE 802.3af/at
  • PoE maitinimo tipasEnd-span
  • PoE išdėstymas1/2/4/5(+), 3/6/7/8(-)
  • PoE biudžetas30W max for each port, 370W max for whole switch
  • Port Lightning Protection6kV
  • Darbo sąlygos temperatūra-10℃~50℃, 10%~90% (Non-condensation)
  • Saugykla-40℃~70℃, 5%~90% (Non-condensation)
  • Switch Mode Default modeSwitches in this mode can function as a core switch and all the ports can communicate with each other. QoS mode: UTP3318S-PSB250-M0 port 15, 16, SFP1 and SFP2 serve as uplink ports, ports 1-8 serve as high priority port. All ports can communicate with each other separately. UTP3324S-PSB250-M0, UTP3324S-PSB410-M0 port 23, 24, SFP1 and SFP2 serve as uplink ports, ports 1-8 serve as high priority port. All ports can communicate with each other separately. CCTV mode: UTP3318S-PSB250-M0 transmission distance of ports 9-14 is extended up to 250m, but the data rate is limited to 10Mbps. UTP3324S-PSB250-M0, UTP3324S-PSB410-M0 transmission distance of ports 17-22 is extended up to 250m, but the data rate is limited to 10Mbps. VLAN mode: UTP3318S-PSB250-M0 ports 1-14 are isolated from each other but able to communicate with ports 15, 16, SFP1 and SFP2. UTP3324S-PSB250-M0, UTP3324S-PSB410-M0 ports 1-22 are isolated from each other but able to communicate with ports 23, 24, SFP1 and SFP2.
SWITCHUTP3324SPSB410M0
4.84 kg